A variety of USB descriptor structures have been manually "unpacked". Instead of using the struct, their members were unpacked into the struct they were nested in. Additionally sizeof()'s were commented in favor of manual calculation of structure sizes. After uncommenting these changes, the USB CDC peripheral stopped correctly configuring with the host. The root problem with the structures is that GCC is padding them. By applying __attribute__((__packed__)), these problems are fixed. I removed all the instances of the workaround I saw within the USB code. Signed-off-by: RJ Ryan <rryan@mit.edu>