diff options
author | Marti Bolivar <mbolivar@leaflabs.com> | 2011-05-27 15:53:02 -0400 |
---|---|---|
committer | Marti Bolivar <mbolivar@leaflabs.com> | 2011-05-27 16:02:20 -0400 |
commit | 8dcb324c1fc847c082e5380617352af3cd545c1b (patch) | |
tree | e99e2d7e4d8ca37bf5f448fe9f6c11b9ac3811a4 /docs/source/adc.rst | |
parent | eb25aa623fb3cdbc131c966fe2c516caa85da7a7 (diff) | |
download | librambutan-8dcb324c1fc847c082e5380617352af3cd545c1b.tar.gz librambutan-8dcb324c1fc847c082e5380617352af3cd545c1b.zip |
Docs: Fix ADC voltage source error.
Vdda, not Vcc.
Diffstat (limited to 'docs/source/adc.rst')
-rw-r--r-- | docs/source/adc.rst | 10 |
1 files changed, 5 insertions, 5 deletions
diff --git a/docs/source/adc.rst b/docs/source/adc.rst index a749201..18c54ab 100644 --- a/docs/source/adc.rst +++ b/docs/source/adc.rst @@ -45,11 +45,11 @@ together, or the same voltage can even be sampled by multiple ADC pins at the same time. Another important factor when taking a voltage reading is the -reference voltages that the sample is being compared against. In the -case of the Maple, the high reference is |vcc| and the low reference -is ground. This means that noise or fluctuations on either |vcc| or -ground will affect the measurement. It also means that the voltage you -are trying to sample must be between ground and 3.3 V. +reference voltages that the sample is being compared against. For +Maple, the high reference is |vdda| and the low reference is ground. +This means that noise or fluctuations on either |vdda| or ground will +affect the measurement. It also means that the voltage you are trying +to sample must be between ground and 3.3 V. .. _adc-range: |